" ... (b) If any test specimen shows defective machining or develops flaws, it may be discarded and another specimen substituted. (c) If the percentage of elongation of any tension test specimen is less than that specified in Section 5 (a) and any part... "
Code of Federal Regulations: Containing a Codification of Documents of ... - Page 223
1953
Full view - About this book

Bulletin, Volume 20, Part 1

American Society for Testing Materials - Building materials - 1920 - 868 pages
...and one bend test shall be made from each melt; except that if material from one melt differs f in. or more in thickness, one tension and one bend test...tension test specimen is less than that specified in Section 6 (a) and any part of the fracture is outside the middle third of the gage length, as indicated...
Full view - About this book

ASME Transactions, Volume 36

American Society of Mechanical Engineers - Mechanical engineering - 1915 - 1466 pages
...and one bend test shall be made from each melt; except that if material from one melt differs % in. or more in thickness, one tension and one bend test...tension test specimen is less than that specified in Par. 67, and any part of the fracture is more than % in. from the center of the gage length of a 2-in....
Full view - About this book

Transactions of the American Society of Mechanical Engineers, Volume 36

American Society of Mechanical Engineers - Mechanical engineering - 1915 - 1408 pages
...and one bend test shall be made from each melt; except that if material from one melt differs % in. or more in thickness, one tension and one bend test...tension test specimen is less than that specified in Par. 67, and any part of the fracture is more than % in. from the center of the gage length of a 2-in....
Full view - About this book

The Design of Steam Boilers and Pressure Vessels

George Bartholomew Haven, George Wright Swett - Pressure vessels - 1915 - 450 pages
...quench-bend test shall be made from each plate as rolled. (ft) If any test specimen shows defective machining or develops flaws, it may be discarded and another...tension test specimen is less than that specified in Section 6 (a) and any part of the fracture is outside the middle third of the gage length, as indicated...
Full view - About this book

Report of Proceedings of the ... Annual Convention of the ..., Volume 48

American Railway Master Mechanics' Association - Railroad engineering - 1915 - 916 pages
...rolled and in addition one homogeneity test shall be made from each plate made into fire-box material. (b) If any test specimen shows defective machining...substituted. (c) If the percentage of elongation of any test specimen is less than that specified in Section 7, and any part of the fracture is outside the...
Full view - About this book

A.S.T.M. Standards

Materials - 1919 - 384 pages
...and one bend test shall be made from each melt; except that if material from one melt differs f in. or more in thickness, one tension and one bend test...tension test specimen is less than that specified in Section 6 (a) and any part of the fracture is outside the middle third of the gage length, as indicated...
Full view - About this book

Tentative Boiler Safety Orders Prepared by a Sub-committee Representing ...

California. Industrial Accident Commission - Steam-boilers - 1916 - 172 pages
...and one bend test shall be made from each melt; except that if material from one melt differs % in. or more in thickness, one tension and one bend test...tension test specimen is less than that specified in Par. 67, and any part of the fracture is more than % in. from the center of the gage length of a 2-in....
Full view - About this book

Concrete Construction for Rural Communities

Roy A. Seaton - Concrete construction - 1916 - 246 pages
...Bessemer steel; except that if material from one melt differs f in. or more in thickness or diameter, one tension and one bend test shall be made from both...tension test specimen is less than that specified in Section 8(a) and any part of the fracture is outside the middle third of the gage length, as indicated...
Full view - About this book

Boiler Safety Orders: Effective January 1, 1917

California. Industrial Accident Commission - Steam-boiler inspection - 1916 - 170 pages
...one melt differs % in. or more in thickness, one tension and one bend test shall be made from botli the thickest and the thinnest material rolled. b If...tension test specimen is less than that specified in Par. 67, and any part of the fracture is more than % in. from the center of the gage length of a 2-iu....
Full view - About this book

A.S.T.M. Standards

Materials - 1916 - 806 pages
...of Tests. 8. (a) If specified by the purchaser, one tension test shall Tension Test Specimens. 197 (b) If any test specimen shows defective machining...substituted. (c) If the percentage of elongation of any test specimen is less than that specified in Section 6 and any part of the fracture is more than J...
Full view - About this book